Skip navigation

REVO legacy head

Technical specifications
Documents
Part numbers
Additional information
REVO beim Scannen eines Zylinderkopfs

A highly accurate dynamic measuring head and probe system which maximises measurement throughput.

Product tree

Increased measuring speed

  • Up to 500 mm/sec resulting in increased part throughput
  • Data collection rates up to 4,000 points per second
  • Infinite positioning and five-axis motion reduces non productive transitions between features
  • Rapid calibration with all positions inferred means more time measuring

WITH high system accuracy

  • 5-axis scanning minimises CMM motion and the associated dynamic errors
  • Stylus wear minimised by extremely low scanning forces
  • Infinite positioning and five-axis motion aid access to difficult features
  • Flexible tip sensing further adds to the systems' accuracy and flexibility

AND great flexibility

  • Maximum reach up to 800 mm* with maintained effective working length
  • Probe and stylus changing capability allowing flexibility and future probing technology compatibility
  • Renishaw UCCserver software application (based on I++ DME command protocol) provides the interface for REVO control
  • The removable probe system, used in conjunction with a low cost changer, provides added system flexibility

* From centre of head rotation

REVO probe comparison chart


RSP2

RSP3

SFP1

Tip sensing

Yes

No

Yes

Cranked styli

No

50 mm

Yes

Sensing axes

XY scan

XYZ touch

XYZ scan

XYZ touch

n/a

Probe changing

Yes

Yes

Yes

Stylus changing

Yes

Yes

Yes


Dimensions

Dimensions of the REVO head

NOTE: Dimensions in mm (in).

Specification


Operating temperature

14 °C to 30 °C (57 °F to 86 °F)

Storage temperature

-10 °C to +70 °C (14 °F to 158 °F)

Weight (excluding probe and cables)

1.75 kg

Height (overall)

239 mm (9.41 in)

B-axis

92 mm (3.62 in ) square

A-axis swept diameter

118 mm (4.65 in)

Movement speed

3 revs/sec

A-axis rotation angle

-5° to +120°

B-axis rotation angle

Continuous

Angular resolution

0.08 arc sec (0.4 µm/100 mm)

Bearings

Air (refer to user guide for detail)

Change rack system

RCP TC for probe changing / RCP for stylus changing

Mounting

Quill mounting in the vertical orientation only (adaptor may be required)