So that a controller can function without a readhead being connected, a blanking plug is required. This removes any signals coming from the readhead on that axis including and any errors signals.
15-way high-density ‘D' connector and pin confiruration
These are the pin numbers for a female 15-way high-density ‘D' connector

These are the pin configurations for both RGH22 and RGH24 read heads using the 15-way high-density ‘D' connector.
Pin number | Function |
1 | External set up |
2 | 0 V |
3 | -Error |
4 | -Ref. mark |
5 | -B signal |
6 | -A signal |
7 | +5 V supply |
8 | +5 V supply sensing |
9 | 0 V sensing |
10 | Limit switch |
11 | +Error |
12 | +Ref. mark |
13 | +B signal |
14 | +A signal |
15 | Inner screen |
Shell | Shell and screen |
Blanking connector for unused readhead connections
These are the pins that need to be connected together on the blanking plug to allow the controller to function without having a readhead plugged in. The pins need to be shorted to each other as the diagram shows.

Requirements
Hardware
- 15-way high-density ‘D' connector - male
Tooling
- Wire cutters / strippers
- Soldering iron and solder