CMM controller cabinet maintenance
Authorised personnel service and maintenance
NOTE: There is hazardous live 240 Vac present within the cabinet.
CAUTION: Ensure that mains is fully isolated before any service or maintenance operations are carried out.
CAUTION: Following any service and maintenance an inspection of the mains wiring and protective bonding should be carried followed by a PAT test.
Periodic checks
It is advised to periodically check the cabinet and cable management system for damage or wear to key parts. Any visible damage or wear should be reported to the system maintenance engineer.
User serviceable parts
The cabinet has two fans which are the only user serviceable components.
Cooling fans
CAUTION: Ensure the cabinet is switched OFF before changing the filter.
The two cabinet fans are used to push air out of the cabinet for cooling the equipment within. One is located on each lower side panel.

The fans have mesh filters. Renishaw recommends that these are changed at least every 12 months. If the kiosk is located in an environment with high levels of particulates in the air, the filters should be changed at more regular intervals.
Description | Part number |
---|---|
Mesh filter replacement kit (pack of five) | A-6509-0400 |
These filters should only be ordered from Renishaw.
Cleaning
The CMM controller cabinet should be cleaned with a dry, lint-free cloth.