UCC2 and UCC2-2 maintenance
WARNING: Maintenance should only be carried out after the machine has been isolated from the electrical supply, compressed air supply , or other energy sources in accordance with the machine manufacturer's instructions.
Periodically, check the security of mounting screws and electrical connectors.
Periodical electrical safety checks should include inspecting the mains cable for damage and safe connections. An earth continuity (ground bonding) test may be applied between the protective earth pin of the mains connector and the metal case at a test current of no greater than 25 A.
Periodical safety checks should also include the function of the emergency stop system, including operation of all switches integrated into the system. After operating the emergency stop system, the servo amplifier system should be checked to ensure servo power can be engaged.
Remove dust from the external surfaces with a clean dry cloth as the unit is not sealed against fluids/water.